Semaglutide dosage calculator and complete units chart
Convert a prescribed amount of semaglutide into mL and U-100 syringe units using the concentration on your actual vial. The chart and calculator explain arithmetic; neither selects a dose.
Last editorially updated: · By Jeff Schaeffer
Not medical advice. Talk to your prescriber and pharmacist. Confirm your prescribed dose, product, concentration, device, and instructions before using any calculation. This website cannot choose or change your treatment.
Check prescribed mg against a verified vial concentration
Blank fields are intentional. Copy the numbers from your prescription and pharmacy label; no suggested dose is preselected.
— U-100 units
— mL
Enter both values to see the arithmetic.
Semaglutide units chart: all retained arithmetic examples
Each column is an example concentration in mg/mL, not a claim about available products. Each cell is U-100 volume units. Rows preserve the old lookup information; they are not a recommended dose schedule. Some rows are not labeled doses. Use only the exact dose and concentration confirmed by your prescriber and pharmacy. Values are displayed to four decimal places; this is mathematical precision, not syringe precision.
| Example mg | 1 mg/mL | 2 mg/mL | 2.5 mg/mL | 3 mg/mL | 5 mg/mL |
|---|---|---|---|---|---|
| 0.1 mg | 10 | 5 | 4 | 3.3333 | 2 |
| 0.2 mg | 20 | 10 | 8 | 6.6667 | 4 |
| 0.25 mg | 25 | 12.5 | 10 | 8.3333 | 5 |
| 0.3 mg | 30 | 15 | 12 | 10 | 6 |
| 0.4 mg | 40 | 20 | 16 | 13.3333 | 8 |
| 0.5 mg | 50 | 25 | 20 | 16.6667 | 10 |
| 0.6 mg | 60 | 30 | 24 | 20 | 12 |
| 0.7 mg | 70 | 35 | 28 | 23.3333 | 14 |
| 0.75 mg | 75 | 37.5 | 30 | 25 | 15 |
| 0.8 mg | 80 | 40 | 32 | 26.6667 | 16 |
| 1 mg | 100 | 50 | 40 | 33.3333 | 20 |
| 1.2 mg | 120† | 60 | 48 | 40 | 24 |
| 1.25 mg | 125† | 62.5 | 50 | 41.6667 | 25 |
| 1.5 mg | 150† | 75 | 60 | 50 | 30 |
| 1.7 mg | 170† | 85 | 68 | 56.6667 | 34 |
| 1.75 mg | 175† | 87.5 | 70 | 58.3333 | 35 |
| 2 mg | 200† | 100 | 80 | 66.6667 | 40 |
| 2.4 mg | 240† | 120† | 96 | 80 | 48 |
| 2.5 mg | 250† | 125† | 100 | 83.3333 | 50 |
† More than 100 units means more than 1 mL. Stop and ask the pharmacy to reconcile the prescription and device; do not split injections or improvise a larger device from this chart. To find mL, divide the displayed units by 100. Fractional markings require pharmacist confirmation.
How this is calculated: every formula is written out on this page, the sources are listed at the bottom, and our editorial policy explains how we check and correct numbers.
Comparing GLP-1 program costs?
Use your actual provider quote to estimate the full cost with our cost calculator. You can also review pricing and eligibility directly with a telehealth provider.
SkinnyRxOral and injectable GLP-1 options, with financing.See SkinnyRx options →Disclosure: GLP1 Math may earn a commission if you sign up through these links. It costs you nothing extra and does not change what the calculators show. A provider listing is not a medical recommendation.
Start with three separate facts
A prescription describes an amount of medicine, usually in milligrams. A vial label describes how much medicine is in a volume of liquid, often as milligrams per milliliter. A syringe describes a volume. These are different facts, and leaving out any one of them makes a units answer unreliable. Before entering a number, identify the prescribed mg, the verified mg/mL, and the exact syringe scale your pharmacy supplied. If the directions give only units, ask the pharmacy to write the corresponding mg and mL as well.
The calculator deliberately starts blank. A prefilled concentration can look like a recommendation, especially when a new shipment looks similar to the old one. There is no universal semaglutide vial concentration. The values in our chart are mathematical examples retained from earlier lookup pages, not a list of recommended prescriptions or verified products. Read your current label each time the product changes. Do not choose a nearby column if your strength is absent; enter the exact confirmed concentration instead.
The formula, with the units left attached
Divide prescribed mg by concentration in mg/mL to obtain mL. Then multiply mL by 100 to obtain markings on a U-100 insulin syringe. Written together, U-100 units = prescribed mg ÷ concentration in mg/mL × 100. The mg cancel in the first division, leaving a volume. That cancellation is a useful check: multiplying mg by mg/mL does not produce the unit you need. Use the reverse converter to check the result independently.
For an arithmetic example, suppose a prescription says 0.5 mg and a pharmacist confirms 2.5 mg/mL. Dividing 0.5 by 2.5 gives 0.2 mL. Multiplying 0.2 by 100 gives 20 U-100 units. Reverse the calculation: 20 ÷ 100 × 2.5 = 0.5 mg. These example inputs are not instructions to use that dose. A correct result proves only that those numbers agree mathematically; it cannot establish that they match your prescription or that the product is appropriate for you.
What happens when the concentration changes
Keep the same example prescription of 0.5 mg but change the verified concentration to 5 mg/mL. The required liquid is now 0.1 mL, or 10 U-100 units. The medicine amount has stayed constant while the volume has halved. Drawing the old 20 units from this stronger example vial would contain 1 mg. This is why a familiar syringe number is not a permanent dose identity. The concentration belongs to the current vial, not to the person using it.
A label that states 10 mg in a total of 2 mL describes 5 mg/mL. The division is total medicine divided by total liquid. It does not mean 10 mg/mL, and the container's physical capacity is not the liquid volume. A vial capable of holding several milliliters may contain less than its capacity. If the volume, ingredient, or units are unclear, stop at the input stage. The concentration guide walks through ambiguous labels without guessing missing information.
Read the chart as a matrix, not a dose ladder
Locate the row for the already prescribed amount and the column for the verified concentration. The intersection is a U-100 volume marking. Moving down the rows is not a treatment plan. Several example rows are not doses in an approved product's schedule. Our consolidation preserves the arithmetic people previously found on separate pages while removing the misleading impression that each number deserves its own medical recommendation. For product schedules, use the separate label checkpoint tool and your prescriber's instructions.
Some cells contain repeating decimals. The chart displays four decimal places so the calculation is inspectable, but a syringe cannot necessarily measure those values. A display such as 16.6667 units is not permission to estimate between lines. Likewise, an answer above 100 units exceeds a 1 mL U-100 syringe. The correct response is to have the pharmacy reconcile the prescribed amount, concentration, and measuring device. Do not change the prescription, split an injection, or improvise a dilution to make the chart fit.
Reading the actual U-100 syringe
On a U-100 scale, 100 units corresponds to 1 mL, 50 to 0.5 mL, and 10 to 0.1 mL. The label U-100 matters: another insulin scale does not use this conversion. Capacity and graduation are different. A 30-unit syringe is a smaller container than a 100-unit syringe, but the exact spacing between its lines still has to be checked. Count the intervals between numbered marks rather than assuming each short line represents one unit.
Ask the pharmacist to demonstrate the correct plunger reference edge on your specific device and to watch you read it back. View the barrel at eye level and use the supplied instructions to address bubbles or unclear markings. The diagram on another website cannot establish the precision of the syringe in your hand. Our syringe guide explains the scale; it does not replace in-person training in drawing up and administering medicine.
Pens, missed doses, and storage need product instructions
Do not withdraw medicine from a pen to use this calculator. For selector questions, read why Ozempic clicks cannot be converted to mg with a syringe formula. Ozempic and Wegovy have product-specific devices and instructions, and current labels contain more presentations than older articles describe. There are also oral semaglutide products; the weekly injection rules do not apply to tablets. The fact that two products contain semaglutide does not make their device instructions or missed-dose rules interchangeable. Use the label for the exact product and presentation you received.
For Ozempic injection, the label gives a five-day window after a missed dose; after that, skip it and resume on the regular day. Wegovy injection instead compares the time remaining until the next scheduled dose: more than two days versus less than two days. Its current label directs lower-dose reinitiation of escalation after two or more consecutive missed injections, which requires a prescriber plan. At the exact two-day boundary, ask your pharmacist to resolve the label wording. See the full semaglutide missed-dose guide before applying any rule.
Storage also follows the presentation. For example, the Ozempic multidose pen has a 56-day in-use limit under its specified conditions; that is not a universal limit for compounded vials. Compounded medicine needs the dispensing pharmacy's beyond-use date and instructions after puncture. Do not derive storage life from how much liquid remains. If a shipment was frozen, overheated, or arrived without understandable directions, contact the pharmacy before use. Arithmetic cannot determine whether a medicine is still usable.
Resolve discrepancies before they become injections
A wrong concentration, a misplaced decimal, and an incorrect syringe scale can all produce plausible-looking answers. Write an example calculation in a single line with its units, then have the pharmacist compare it to the prescription. For leakage or a stopped pen, our incomplete GLP-1 injection guide explains what to report. If you already injected an uncertain amount, contact your prescriber, pharmacist, or Poison Control promptly instead of repeatedly recalculating online. In the United States, Poison Control is available at 1-800-222-1222. For severe symptoms or a medical emergency, seek emergency care. This calculator cannot assess exposure or symptoms.
Frequently asked questions
Is 20 units a semaglutide dose?
It is a volume on a U-100 scale: 0.2 mL. At an example concentration of 2.5 mg/mL it contains 0.5 mg; at 5 mg/mL it contains 1 mg. Your pharmacy must confirm which concentration and prescribed amount apply.
Can I use the total mg printed on the vial?
Not as the concentration unless the label explicitly says mg/mL. If both total mg and total solution mL are clearly stated, divide them. If either is missing, ask the pharmacy instead of treating container size as liquid volume.
Why are unusual numbers included in the table?
The table consolidates historical arithmetic lookups. Inclusion is not evidence that a number is an approved dose or suitable for any person. Use the prescription first, and read product schedules separately.
Should I round to the closest line?
Do not select a clinical rounding rule from this website. Ask the pharmacist whether the calculated volume can be measured with the supplied syringe and how the prescription should be reconciled if it cannot.
Can I count pen clicks instead?
This calculator does not count clicks, extract pen contents, or alter a fixed-dose device. Follow the exact product Instructions for Use. A vial conversion table does not authorize modifying a pen.
Does the calculator decide whether I should increase?
No. It has no information about response, side effects, medical history, or your treatment plan. A numerically valid input is not a recommendation to take that amount. Contact your prescriber about changes.
Where do I report a wrong table entry?
Email [email protected] with the page address, example inputs, expected arithmetic, and the conflicting cell. Do not include a prescription number or medical record. Confirm any real measurement with your pharmacy while a report is reviewed.